CONFIDENTIAL
Paper roll Miscellaneous commands ESC ( A
Ver. 10.05 p. 405
ESC ( A pL pH fn n c t1 t2 <Function 97 > (TM-U230)
[Name] Beep integrated beeper in TM-U230 models
[Format] ASCII ESC ( A pL pH fn n c t1 t2
Hex 1B 28 41 05 00 61 n c t1 t2
Decimal 27 40 65 5 097n c t1t2
[Range] (pL + pH × 256) = 5 (pL = 5, pH = 0)
fn = 97
n = 100
0 ≤ c ≤ 63
0 ≤ t1 ≤ 255
0 ≤ t2 ≤ 255
[Description] Beeps the integrated beeper.
• c specifies times of beeping.
• t1 specifies beeping time (t1 × 100 ms).
• t2 specifies time for stop beeping (t2 × 100 ms).
[Notes]
■ This function repeats integrated beeper control of [(t1 × 100 ms) beep/ (t2 × 100 ms) stop] c times.
■ If this command is newly processed during beeping of the buzzer, the current process for beeping the
buzzer is stopped and the new process for beeping the buzzer is started.
■ Integrated beeper beeping by this function stops due to any of the following factors.
• Finish specification of (c).
• Offline factor specified by Function 98 has occurred.
• Factors specified by Function 99 have occurred.
• Reset or power off.