CONFIDENTIAL
Paper roll Miscellaneous commands ESC ( A
Ver. 10.05 p. 405
ESC ( A pL pH fn n c t1 t2 <Function 97 > (TM-U230)
[Name] Beep integrated beeper in TM-U230 models
[Format] ASCII ESC ( A pL pH fn n c t1 t2
Hex 1B 28 41 05 00 61 n c t1 t2
Decimal 27 40 65 5 097n c t1t2
[Range] (pL + pH × 256) = 5 (pL = 5, pH = 0)
fn = 97
n = 100
0 c 63
0 t1 255
0 t2 255
[Description] Beeps the integrated beeper.
c specifies times of beeping.
t1 specifies beeping time (t1 × 100 ms).
t2 specifies time for stop beeping (t2 × 100 ms).
[Notes]
This function repeats integrated beeper control of [(t1 × 100 ms) beep/ (t2 × 100 ms) stop] c times.
If this command is newly processed during beeping of the buzzer, the current process for beeping the
buzzer is stopped and the new process for beeping the buzzer is started.
Integrated beeper beeping by this function stops due to any of the following factors.
Finish specification of (c).
Offline factor specified by Function 98 has occurred.
Factors specified by Function 99 have occurred.
Reset or power off.