CONFIDENTIAL
Paper roll Two-dimension code commands GS ( k
Ver. 10.05 p. 529
Using <Function 382> of this command, the size of the symbol printed with <Function 381> can be
acquired.
[Notes for composite symbol processing (when cn = 52 is specified)]
The composite symbol (line element/2D composite element) symbol data specified by <Function 480> of
this command (d1...dk) is temporarily stored in the archive area of the printer and is printed by <Function
481>.
The setting value of <Function 467> and <Function 472> is used when processing <Function 481> and
<Function 482> of this command. Furthermore, the setting value of <Function 471> is used when
processing RSS Expanded Stacked. If the printing area is narrow, it may not be possible to print the symbol.
The same symbol can be printed by executing <Function 481> repeatedly after executing <Function 480>
of this command.
Composite symbols with a different combination can be printed by resending other symbol data with
either of the line element or 2D composite element as it is.
Step 1) Specify <Function 480: (a = 49, b = 65)>, and send the 2D composite element data.
Step 2) Specify <Function 480: (a = 48, b = 70)>, and send the line element data.
Step 3) Print the composite symbol of which RSS-14 is the line element with <Function 481>.
Step 4) Specify <Function 480: (a = 48, b = 74)>, and send the line element data.
Step 5) Print the composite symbol of which RSS Limited is the line element with <Function 481>.
Using <Function 482> of this command, the size of the symbol printed with <Function 481> can be
acquired.
[Notes for transmission process]
Transmission process is performed by <Function 082>, <Function 182>, and <Function 282>. When you use
this command, follow these rules.
After the host PC transmits the function data, the printer will send response data or status data back to
the PC. Do not transmit more data from the PC until the corresponding data is received from the
printer.
When operating with a serial interface, be sure to configure operation so that the host computer uses
these functions only when it is READY.