CONFIDENTIAL
Paper roll Two-dimension code commands GS ( k
Ver. 10.05 p. 538
GS ( k <Function 068>
[Name] PDF417: Set the row height
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 44 n
Decimal 29401073 0 48 68 n
[Range] (pL + pH × 256) = 3 (pL = 3, pH =0)
cn = 48
fn = 68
TM-T90, TM-T88IV, TM-T70, TM-L90, TM-P60: 2 ≤ n ≤ 8
[Default] TM-T90, TM-T88IV, TM-T70, TM-L90, TM-P60: n = 3
[Description] Sets the row height for PDF417 to [n × (the width of the module)].
[Notes]
■ Settings of this function affect the processing of Functions 081 and 082.
■ Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is
turned off.
[Model-dependent variations] TM-T90, TM-L90, TM-T88IV, TM-T70, TM-P60
TM-T90, TM-L90
The module height influences the recognition rate of the symbol.
The module height is recommended to be set to 3-5 times the module width.
The recognition rate might decrease when the vertical size of the symbol is 5 mm {0.2"} or less.
The vertical size of the symbol can be confirmed by the transmission data of Function 082.
TM-T88IV, TM-T70
This function is not supported in the Japanese specification.
The module height influences the recognition rate of the symbol.
The module height is recommended to be set to 3-5 times the module width.
The recognition rate might decrease when the vertical size of the symbol is 5 mm {0.2"} or less.
The vertical size of the symbol can be confirmed by the transmission data of Function 082.