6-42 Disassembly, Assembly, and Adjustment Rev. A
Confidential
Roll paper unit
Follow the steps below to disassemble the unit.
1. Remove the covers so you can access the
Mechanism assembly, M-J8000
. See the “Covers
and upper case” section in this chapter.
2. Remove the connector box and remove the
Cover, connector board.
See the “Connector
box” section in this chapter.
3. Remove the three screws (C.C.S-tite, 3 x 5) from the
Pump unit
and set the
Pump unit
down
safely.
Figure 6-62 Removing the screws
4. Unhook all the cables from the two clamps shown below.
Figure 6-63 Unhooking the cables