11. Remote Control
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 271
Remote
Command
Send
command
Data Description
Input
Acceptance
Condition (*1)
SetVariable
&H56
name],
[value]
(type size)
(&H2C),[type]
(1Byte)
Set the value in the backup (Global Preserve)
parameter
Example) Set &H0 to Global Integer g_Status
&H02&H56&H67&H5F&H53&H74&H61&H74
&H75&H73&H2C&H0000&H2C&H03&H03&
Ready ON
GetStatus
‘S’
&H53
Acquire the Controller state
time (*10)
Execute
‘X’
&H58
Command string
Execute the command (*8) (*9)
Example) Execute ‘print here’
&H02&H58&H22&H70&H72&H69&H6E&H7
4&H20&H68&H65&H72&H65&H22&H03&H
10
Ready ON
Error OFF
EStop OFF
Safeguard
OFF
Abort
‘A’
&H41
Abort the command execution (*8)
(*1) The Controller state bit from GetStatus.
(*2) Execute the function specified in the Main[Function No.].
(*3) Pause command is not available for “NoPause task” and “NoEmgAbort task”.
For the details, refer to the help or the section “Pause” in the EPSON RC+5.0 Language reference manual.
(*4) I/O output will be turned OFF and the robot parameter will be initialized.
For the details, refer to the help or the section “Reset” in the EPSON RC+5.0 Language reference manual.
(*5) The robot parameter will be initialized.
For the details, refer to the help or the section “Motor” in the EPSON RC+5.0 Language reference manual.
(*6) Parameter type