5. The EPSON RC+ 5.0 GUI
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 123
Include project files in when status exported
This preference allows you to configure whether project files are included or not when the
controller status is exported. See Tools | Controller for information on exporting and
viewing controller status. The default setting is on.
The project using Vision Guide cannot perfectly be stored by the Status storage. This is
beca
use some files are not transferred to the Controller.
If you are using Vision Guide, please back up the project files with RC+.
Safeguard open stops all tasks
Check this option to cause all tasks to stop when the safeguard is open.
This option can be used in applications where pause / continue are not required.
The default setting is off.
When the version of the connected RC180 controller firmware is Ver.1.0.*.*, this check
box cannot be checked.
Enable CP – PTP connection when CP is on
This preference allows you to overlap the trajectories of CP motion and PTP motion during
CP ON.
Over-speed error or Over-acceleration-speed error may occur according to the motion
acceleration / deceleration speed setting. If the error occurs, adjust the acceleration /
deceleration speed setting or uncheck this checkbox.
Auto LJM (Least Joint Motion)
This preference allows you to enable Auto LJM at the controller start up. To disable Auto
LJM temporarily, use AutoLJM Off command.
If Auto LJM is enabled at all times, this function automatically adjusts the posture of the
manipulator to reduce the motion distance, even when you intended to move the joint
widely. Therefore, it is recommended to disable Auto LJM at the controller start up and
operate the manipulator as you desired using AutoLJM On command or LJM function.
Disable Point flag check
This preference allows you to continue operation even when point flags, one was specified
as a target point and the other one after the motion completion, do not match in a CP
motion.
However, if the flags do not match at the transferring point while CP On is used, the
manipulator will stop at the point and the motion will not become a path motion.
Motor off when Enable switch off in Teach Mode
This preference is read-only. It shows whether motors will be turned off when the Enable
switch is off during Teach Mode.
)