Specification
(
STANDARD
)
71 70
E
<Function 2> GS ( C pL pH m fn b c1 c2 (fn = 2, 50)
[Name] Transmit the data in the specified record
[Format] ASCII GS ( C p
L pH m fn b c1 c2
Hex 1D 28 43 pL pH m fn b c1 c2
Decimal 29 40 67 pL pH m fn b c1 c2
[Range] (p
L + pH × 256) = 5 (pL = 5, pH = 0)
m = 0
fn = 2, 50
b = 0
32 c1 126
32 c2 126
[Description] Transmits the data for the record specified by the key codes (c1, c2) in the NV user
memory.
<Function 3> GS ( C pL pH m fn b (fn = 3, 51)
[Name] Transmit capacity of the NV user memory currently being used
[Format] ASCII GS ( C p
L pH m fn b
Hex 1D 28 43 pL pH m fn b
Decimal 29 40 67 pL pH m fn b
[Range] (p
L + pH × 256) = 3 (pL = 3, pH = 0)
m = 0
fn = 3, 51
b = 0
[Description] Transmits the number of bytes of memory used in the NV user memory.
<Function 4> GS ( C pL pH m fn b (fn = 4, 52)
[Name] Transmit the remaining capacity of the NV user memory
[Format] ASCII GS ( C p
L pH m fn b
Hex 1D 28 43 pL pH m fn b
Decimal 29 40 67 p
L pH m fn b
[Range] (p
L + pH × 256) = 3 (pL = 3, pH = 0)
m = 0
fn = 4, 52
b = 0
[Description] Transmits the number of bytes of remaining memory (unused area) in the NV user
memory.