Seitenansicht 19
Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEETNEXT
TM-P60
Specification
(STANDARD)
E
9 8
3) MCBF: 16,000,000 lines printed
(This is an average failure interval based on failures relating to
wearout and random failures up to the life of 10,000,000 lines printed.)
1.14 Environmental Conditions for Operating
1) Operating: <Power supply: Battery>
Temperature: 0 to 50°C {32 to 122°F} (except for print quality)
Humidity: 10 to 90% RH (except for paper)
<Power supply: AC adapter>
Temperature: 0 to 45°C {32 to 113°F} (except for print quality)
Humidity: 10 to 90% RH (except for paper)
NOTE: The temperature above applies only if power management is enabled.
When power management is disabled, the highest temperature is 40°C.
2) Print quality to be guaranteed:
Temperature: 5 to 45°C {41 to 113°F}
Humidity: 10 to 90% RH
[%RH]
10
20
40
60
80
90
0 10 20 30 40 50
45°C, 50%
40°C, 65%
Environmental temperature [°C]
34°C, 90%
Relative Humidity
50°C, 35%
: Print quality is guaranteed
: Operating is guaranteed
+
Figure 1.13.1 Temperature and Humidity Range for Operating to be Guaranteed
3) Battery charging: Temperature: 0 to 40°C {32 to 104°F}
Humidity: 10 to 90% RH
1.15 Ways to wear the Printer
1) Belt clip
2) Shoulder strap (option)
G