5–36 EPSON
SED1225 Series
Display Mode
End of initialization
RAM address set input
RAM (data) write input
Display the written contents.
Standby Mode
(1) Setting the standby mode
<1> Display on/off control command input
<2> Power save command input
<3> Power supply control command input
- D off (display)
- PS on (power save)
O on (oscillation)
- P off
End of initialization
Starts the standby mode.
Displays only the static icon.
Normal operation - Power save is cleared and oscillating circuit turns on.
(2) Clearing the standby mode
Standby mode
Wait for 20 microseconds or more.
Returns to normal operation (original state).
<1> Power save command input
<2> Power supply control command inpu
<3> Display on/off command input - D on (display)
- PS off (power save)
O on (oscillation)
- P on
O on (oscillation)
- P off